YASKAWA FS100 Maintenance Manual page 318

Hide thumbs Also See for FS100:
Table of Contents

Advertisement

Alarm
Alarm Name
Sub
Number
Code
4943
AVERAGING TIME
ERROR (SERVO)
4944
POSITION LOOP GAIN
ERROR (SV)
4945
MOTION COMMAND
DATA ERROR (SV)
4946
PG POWER ON
INCOMPLETE (SV)
4947
SERVO ON MULTIPLE
REQUEST (SV)
4948
ENCODER ALARM
(SERVO)
4953
ENCODER COUNTER
DIFF. ERROR(SV)
4955
AVERAGING DATA
ERROR (SERVO)
Meaning
Cause
Software operation error
occurred
Software operation error
occurred
Software operation error
occurred
Software operation error
occurred
Software operation error
occurred
Software operation error
occurred
Sub Code: Signifies the axis in
Connection failure
which the alarm occurred
Servo control board failure
Software operation error
occurred
Remedy
(1)Reset the alarm.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
{Robot axis}
·Cable between encoders
{External axis}
·Cable between encoders
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
318 of 348