Alarm
Alarm Name
Sub
Number
Code
3
4
5
6
7
4435
UNDEFINED LOCAL-
0
VARIABLE
1
2
3
4
5
6
7
Meaning
Cause
The set data for real type variable
Software operation error
area is incorrect.
occurred
The set data for character-string
Software operation error
type variable area is incorrect.
occurred
The set data for robot-axis
Software operation error
position-type variable area is
occurred
incorrect.
The set data for base-axis
Software operation error
position-type variable (S1D
occurred
parameter) area is incorrect.
The set data for station-axis
Software operation error
position-type variable (S1D
occurred
parameter) area is incorrect.
The byte type variable is not
Setting error
defined.
The integer type variable is not
Setting error
defined.
The double-precision integer-type
Setting error
variable is not defined.
The real-number type variable is
Setting error
not defined.
The character-string type variable
Setting error
is not defined.
The robot-axis position-type
Setting error
variable is not defined.
The base-axis position-type
Setting error
variable is not defined.
The station-axis position-type
Setting error
variable is not defined.
Remedy
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Check the following settings.
·Set the number of local variables to be used in the job header.
(1)Check the following settings.
·Set the number of local variables to be used in the job header.
(1)Check the following settings.
·Set the number of local variables to be used in the job header.
(1)Check the following settings.
·Set the number of local variables to be used in the job header.
(1)Check the following settings.
·Set the number of local variables to be used in the job header.
(1)Check the following settings.
·Set the number of local variables to be used in the job header.
(1)Check the following settings.
·Set the number of local variables to be used in the job header.
(1)Check the following settings.
·Set the number of local variables to be used in the job header.
258 of 348