Alarm
Alarm Name
Sub
Number
Code
6
7
8
9
10
Meaning
Cause
Unused position data file is
Software operation error
destroyed.
occurred
Unused position data file does not
Setting error
exist.
Software operation error
occurred
Position data file is destroyed.
Software operation error
occurred
Position data control information
Software operation error
is destroyed.
occurred
An error occurred in specified
Software operation error
position data number.
occurred
Remedy
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job file.
(4)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Check the following settings.
·The number of steps in job (position data)
Delete unnecessary position data in job and add new position data.
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job file.
(4)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job file.
(4)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job file.
(4)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job file.
(4)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).