Alarm
Alarm Name
Sub
Number
Code
12
13
14
16
18
Meaning
Cause
An error occurred in step number
Software operation error
of the accessed job.
occurred
A job specified at job search did
Software operation error
not exist in the memory.
occurred
There was an instruction that did
Software operation error
not exist in a job because of
occurred
inconsistency of the system
software.
Unused handles were lacking
Setting error
when an attempt was made to
open a job.
Software operation error
occurred
The number of instructions added
Setting error
to a job exceeded 9999.
Remedy
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job file.
(4)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job file.
(4)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job file.
(4)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Check the following settings.
·The number of call job stacks
Set the job configuration that decreases the number of call job stacks.
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job file.
(4)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Check the following settings.
·The number of steps in job
Delete unnecessary instructions in job and add new instructions.