Alarm
Alarm Name
Sub
Number
Code
1831
HWBB FB ERROR
(PLD2)
1832
ESP_OUT FB ERROR
(PLD1)
1833
ESP_OUT FB ERROR
(PLD2)
1834
M-SAFETY WATCHDOG
ERROR (PLD1)
1835
M-SAFETY WATCHDOG
ERROR (PLD2)
1836
M-SAFETY WATCHDOG
ERROR (PLD3)
1837
M-SAFETY 24V POWER
SUPPLY ERROR
Meaning
Cause
Mounting base unit failure
Machine safety board failure
Servo control board failure
Machine safety board failure
Machine safety board failure
Machine safety board failure
Machine safety board failure
Machine safety board failure
Main CPU board failure
Software operation error
occurred
Connection failure
Remedy
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the controller. Save the CMOS.BIN before
replacement to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
167 of 348