Alarm
Alarm Name
Sub
Number
Code
4605
SETTOOL ERROR
1
4606
LACK OF GLOBAL
VARIABLE AREA
4607
WRONG EXECUTION
1
OF MACRO INST
2
3
5
6
4608
WRONG EXECUTION
1
OF GETARG INST
2
3
4611
OVER OPTON INST
EXECUTION LIMIT
4612
TSYNC ERROR
Meaning
Cause
The difference between the
Setting error
current tool constant and a new
set value exceeded the allowable
range (parameter set value).
Software operation error
occurred
The execution macro job is not
Setting error
set.
The interrupt macro job is not set.
Setting error
An attempt was made to start the
Setting error
job that could not be started by
the macro instruction.
An error occurred in the operation
Software operation error
process of job call stack when the
occurred
execution of macro instruction
was cancelled.
Incorrect macro number
Software operation error
occurred
The job argument is not set.
Setting error
No number of the specified job
Setting error
argument
The data types of job argument
Setting error
disagreed.
Setting error
Sub code: the number of
Setting error
synchronizations of the first
executed TSYNC
Remedy
(1)Check the following settings.
·Correct the job so that the setting value of tag is allowable value.
·Set the allowance amount of the tool data automatic setting function maximum
deviation (S3C1192) to large value.
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Check the following settings.
·Check the settings for execution macro job.
(1)Check the following settings.
·Check the settings for interrupt macro job.
(1)Check the following settings.
·Check the settings for macro job.
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Check the following settings.
·Check the settings for jobs.
(1)Check the following settings.
·Check the settings for jobs.
(1)Check the following settings.
·Check the settings for jobs.
(1)Check the following settings.
·Check the settings for the OPTON instruction. OPTON instruction can use only
the function to five simultaneously.
(1)Check the following settings.
·Check the settings for the number of synchronizations of the TSYNC
instruction.