YASKAWA FS100 Maintenance Manual page 169

Hide thumbs Also See for FS100:
Table of Contents

Advertisement

Alarm
Alarm Name
Sub
Number
Code
4000
MEMORY ERROR
(TOOL FILE)
4001
MEMORY ERROR
(USER COORD FILE)
4002
MEMORY ERROR
(SV MON SIGNAL FILE)
4004
MEMORY ERROR
(HOME POS FILE)
4005
MEMORY ERROR
(SECOND HOME POS)
4012
MEMORY ERROR
(LINK SERVOFLOAT)
Meaning
Cause
Sub Code: Tool number
Data error
Main CPU board failure
Sub Code: User coordinate
Data error
number
Main CPU board failure
Data error
Main CPU board failure
Data error
Main CPU board failure
Data error
Main CPU board failure
Sub Code: Condition file number
Data error
Remedy
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the tool file in maintenance mode, and
then load the tool file saved in the external memory device.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the user coordinates file in maintenance
mode, and then load the user coordinates file saved in the external memory
device.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the servo monitor signal file in
maintenance mode, and then load the servo monitor signal file saved in the
external memory device.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the home positioning file in maintenance
mode, and then load the home positioning file saved in the external memory
device.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the second home positioning file in
maintenance mode, and then load the second home positioning file saved in
the external memory device.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the link servo float condition file in
maintenance mode, and then load the link servo float condition file saved in the
external memory device.
169 of 348

Advertisement

Table of Contents
loading