YASKAWA FS100 Maintenance Manual page 304

Hide thumbs Also See for FS100:
Table of Contents

Advertisement

Alarm
Alarm Name
Sub
Number
Code
1081
1082
1083
1084
2045
2046
2065
Meaning
Cause
In a file server task, request
Software operation error
mail data error detected.
occurred
IP address duplicated.
IP address setting error
In a file server task, request
Software operation error
error occurred.
occurred
Failed in the endian
Software operation error
conversion.
occurred
In a file server task, receive
Software operation error
data area overflow.
occurred
In a RC connect management
Software operation error
task , send error detected.
occurred
Failed in the endian
Software operation error
conversion.
occurred
Detect RC server task send
Software operation error
error.
occurred
Remedy
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your YASKAWA representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)The IP address is duplicated with the FS100 controller. Confirm the
IP address of the communication target.
(3)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your YASKAWA representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your YASKAWA representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your YASKAWA representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your YASKAWA representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your YASKAWA representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your YASKAWA representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your YASKAWA representative about
occurrence status (operating procedure).
304 of 348