Alarm
Alarm Name
Sub
Number
Code
4
5
6
7
8
4652
TRQ MEASURE MODE
SET ERROR(SV)
4653
TRQ MEASURE MODE
CANCEL ERROR(SV)
4654
WRONG EXECUTION
1
OF SETREG INST
4655
WRONG EXECUTION
1
OF GETREG INST
4656
WRONG EXECUTION
1
OF SETPRM INST
2
Meaning
Cause
Pelletize completion universal
Setting error
output number range exceeds the
limit.
During the pelletize start
Setting error
instruction execution, the pelletize
start instruction is executed again
(double execution).
The value of the pelletizing
Setting error
number present value output
register (or I variable) is more
than the total number output
register (or I variable).
Pelletize completion universal
Setting error
output signal is turned ON at
pelletize start instruction
execution.
Pelletize end instruction is not
Setting error
registered.
Software operation error
occurred
Software operation error
occurred
An attempt was made to change
Setting error
the value of the register currently
used by TMR/CNT.
An attempt was made to acquire
Software operation error
the value of the register not
occurred
existing.
An attempt was made to change a
Setting error
parameter other than the cube-
related parameter.
The SETPRM instruction was
Setting error
executed while another system
was in execution.
Remedy
(1)Check the following settings.
·Change the pelletize completion universal output signal number of the
pelletizing condition setting file in the user output signal point of contact number.
(1)Check the following settings.
·Delete the pelletize start instruction in the pelletize section.
(1)Check the following settings.
·Check if the pelletizing number of current position output register (or I variable)
and total number of output register (or I variable) is not changed by another
function.
(1)Check the following settings.
·Reset the pelletize completion universal output signal.
(1)Check the following settings.
·Register the pelletizing end instruction.
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Check the following settings.
·The SETREGM instruction cannot change the register values used in TMR/
CNT. Correct the setting of tag that specifies register number of SETREG
instruction.
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Check the following settings.
·The SETPRM instruction cannot change the parameter values other than the
parameter related to the cube. Correct the setting of tag that specifies
parameter number of SETPRM instruction.
(1)Check the following settings.
·The SETPRM instruction cannot execute while another system is operating.
Correct the job.
296 of 348