YASKAWA FS100 Maintenance Manual page 177

Hide thumbs Also See for FS100:
Table of Contents

Advertisement

Alarm
Alarm Name
Sub
Number
Code
4
5
6
7
4114
TRANSMISSION
1
HARDWARE ERROR
2
3
4
5
4115
TRANSMISSION
1
SYSTEM BLOCK
2
Meaning
Cause
Heading length is too long.
Setting error
The header No. error
Setting error
The text length exceeded 256
Setting error
characters.
Illegal data received
Setting error
Overrun error
Communication error
Parity error
Communication error
Framing error
Communication error
Transmission timeout (timer A)
Communication error
Transmission timeout (timer B)
Communication error
Received EOT while waiting ACK. Communication error
Received EOT while waiting ENQ. Communication error
Remedy
(1)Reset the alarm.
(2)If the alarm occurs again, send EOT code to release the data link and then
check that the sending side data is correctly set.
(3)Check that the communication setting is correct.
(1)Reset the alarm.
(2)If the alarm occurs again, send EOT code to release the data link and then
check that the sending side data is correctly set.
(3)Check that the communication setting is correct.
(1)Reset the alarm.
(2)If the alarm occurs again, send EOT code to release the data link and then
check that the sending side data is correctly set.
(3)Check that the communication setting is correct.
(1)Reset the alarm.
(2)If the alarm occurs again, send EOT code to release the data link and then
check that the sending side data is correctly set.
(3)Check that the communication setting is correct.
(1)Reset the alarm.
(2)If the alarm occurs again, check the communication setting and
communication wiring is correct.
(1)Reset the alarm.
(2)If the alarm occurs again, check the communication setting and
communication wiring is correct.
(1)Reset the alarm.
(2)If the alarm occurs again, check the communication setting and
communication wiring is correct.
(1)Reset the alarm.
(2)If the alarm occurs again, check the communication setting and
communication wiring is correct.
(1)Reset the alarm.
(2)If the alarm occurs again, check the communication setting and
communication wiring is correct.
(1)Reset the alarm.
(2)If the alarm occurs again, check the setting of communication or
transmission side data is correctly set.
(1)Reset the alarm.
(2)If the alarm occurs again, check the setting of communication or
transmission side data is correctly set.
177 of 348