YASKAWA FS100 Maintenance Manual page 268

Hide thumbs Also See for FS100:
Table of Contents

Advertisement

Alarm
Alarm Name
Sub
Number
Code
4495
UNDEFINED ROBOT
CALIBRATION
4496
PARAMETER ERROR
1
2
3
4
5
6
7
8
Meaning
Cause
Sub Code: Control group which
Setting error
calibration is not completed
The setting of the manipulator
Setting error
number is incorrect.
Zero is set for the resolution.
Setting error
Zero is set in the feedback pulse
Setting error
parameter.
The setting of L-axis ball-screw
Setting error
data is incorrect.
The setting of U-axis ball-screw
Setting error
data is incorrect.
Zero or a negative value is set for
Setting error
MAXPPS.
Zero or a negative value is set for
Setting error
the maximum acceleration speed.
Zero or a negative value is set for
Setting error
the maximum deceleration speed.
Remedy
(1)Check the following settings.
·Before using the coordinated motion, execute the calibration between
manipulators.
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
268 of 348