Alarm
Alarm Name
Sub
Number
Code
821
CNTR01R SOFTWARE
ERROR
822
CNTR01R WDG ERROR
100
200
300
400
500
600
700
800
Meaning
Cause
Sub Code: Option board.
CNTR01R board failure
Number×100 factor
factor:
1 WDG TIMEOVER
2 ADDRESS ERR(READ)
EXCEPTION
3 ADDRESS ERR(WRITE)
EXCEPTION
4 UNJUST INST
EXCEPTION
5 UNJUST SLOT
EXCEPTION
A Watchdog err was detected in
CNTR01R board failure
the Option #1 board.
A Watchdog err was detected in
CNTR01R board failure
the Option #2 board.
A Watchdog err was detected in
CNTR01R board failure
the Option #3 board.
A Watchdog err was detected in
CNTR01R board failure
the Option #4 board.
A Watchdog err was detected in
CNTR01R board failure
the Option #5 board.
A Watchdog err was detected in
CNTR01R board failure
the Option #6 board.
A Watchdog err was detected in
CNTR01R board failure
the Option #7 board.
A Watchdog err was detected in
CNTR01R board failure
the Option #8 board.
Remedy
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the CNTR01R board. Save the CMOS.BIN
before replacing the board to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the CNTR01R board. Save the CMOS.BIN
before replacing the board to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the CNTR01R board. Save the CMOS.BIN
before replacing the board to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the CNTR01R board. Save the CMOS.BIN
before replacing the board to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the CNTR01R board. Save the CMOS.BIN
before replacing the board to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the CNTR01R board. Save the CMOS.BIN
before replacing the board to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the CNTR01R board. Save the CMOS.BIN
before replacing the board to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the CNTR01R board. Save the CMOS.BIN
before replacing the board to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the CNTR01R board. Save the CMOS.BIN
before replacing the board to be safe.