Alarm
Alarm Name
Sub
Number
Code
910
CPU ERROR
1
(CPU-201R)
920
BUS ERROR
1
(CPU-201R)
950
CPU ERROR
(servo#1)
951
CPU ERROR
(servo#2)
990
SYSTEM ERROR
1
(Main CPU)
1000
ROM ERROR
(Main CPU)
1001
ROM ERROR
10
(SERVO)
Meaning
Cause
An error was detected in the CPU. Main CPU board failure
The JL chip does not operate
Main CPU board failure
normally.
An error was detected in the CPU
Connection failure
of servo board #1.
Servo control board failure
Main CPU board failure
An error was detected in the CPU
Connection failure
of servo board #2.
Servo control board failure
Main CPU board failure
Power Lost Signal Error
Main CPU board failure
Software operation error
occurred
1*:A checksum error occurred in
Servo control board failure
the board or the EEPROM.
(*: axis No.)
Remedy
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the controller. Save the CMOS.BIN before
replacement to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the controller. Save the CMOS.BIN before
replacement to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the controller. Save the CMOS.BIN before
replacement to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the controller. Save the CMOS.BIN before
replacement to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the controller. Save the CMOS.BIN before
replacement to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the controller. Save the CMOS.BIN before
replacement to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the controller. Save the CMOS.BIN before
replacement to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the controller. Save the CMOS.BIN before
replacement to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the controller. Save the CMOS.BIN before
replacement to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.