Alarm
Alarm Name
Sub
Number
Code
-10
-11
-12
4220
SERVO POWER OFF
FOR JOB
4221
SERVO POWER OFF
FOR JOB
4226
COMMUNICATION
1
SERVICE ERROR
100
101
102
103
105
Meaning
Cause
Local variable area shared heap
Software operation error
area.
occurred
An error occurred in exclusive
Software operation error
control.
occurred
An error occurred in exclusive
Software operation error
control when control of the local
occurred
variable was processed.
Sub Code: Control group
Setting error
Sub Code: Control group
Setting error
The communication channel
Setting error
could not be opened/closed at
OPEN/CLOSE instruction
execution.
The communication port is
Setting error
already opened.
The communication port is not
Setting error
opened.
No space was found in data sent
Setting error
buffer.
The setting value for the event
Setting error
queue designation parameter is
incorrect.
The type of output data is
Setting error
incorrect.
Remedy
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Check the following settings.
·Turn OFF the servo power supply, and then turn ON the servo power supply for
the group axis to be operated.
·Turn OFF the servo power supply, and then turn ON the servo power supply for
the group axis to be operated.
(1)Check the following settings.
·Setting of the RS (transmission) parameter
(1)Check the following settings.
The serial port setting
(1)Check the following settings.
The serial port setting
(1)Check the following settings.
The serial port setting
(1)Check the following settings.
·RS157···Set to 1 to 4
(1)Check the following settings.
The serial port setting
229 of 348