YASKAWA FS100 Maintenance Manual page 145

Hide thumbs Also See for FS100:
Table of Contents

Advertisement

Alarm
Alarm Name
Sub
Number
Code
12
1053
SYSTEM ERROR
(EVENT)
1100
SYSTEM ERROR
1101
SYSTEM ERROR
(MAN-MACHINE
MECHA)
1102
SYSTEM ERROR
(MAN-MACHINE APPLI)
1103
SYSTEM ERROR
(EVENT)
1104
SYSTEM ERROR
(CIO)
Meaning
Cause
Unable to prepare the current
Main CPU board failure
position
Software operation error
occurred
Sub Code
Software operation error
1 to 8: Signifies the internal
occurred
software error at event process.
Sub Code
Software operation error
C, B, F : Sub code of unknown
occurred
alarm
RAM software data error
Sub Code
Software operation error
0 to 6: Internal control error in
occurred
software
Sub Code
Software operation error
0 to 526: Internal control error in
occurred
software
Software operation error
occurred
Sub Code
Connection failure
1000_0000: I/O module setting
error
Remedy
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connecting or inserting state of the
following cables or connectors.
·IO module cable of the corresponding slot.
·24V power of the corresponding IO module.
145 of 348

Advertisement

Table of Contents
loading