YASKAWA FS100 Maintenance Manual page 237

Hide thumbs Also See for FS100:
Table of Contents

Advertisement

Alarm
Alarm Name
Sub
Number
Code
4322
AMPLIFIER OVERLOAD
(CONTINUE)
4323
AMPLIFIER OVERLOAD
(MOMENT)
Meaning
Cause
Sub Code: Signifies the axis in
Setting error
which the alarm occurred
Interference error
Setting error
Servo control board failure
Connection failure
Module failure (amplifier)
Module failure (converter)
Sub Code: Signifies the axis in
Setting error
which the alarm occurred
Interference error
Setting error
Servo control board failure
Connection failure
Module failure (amplifier)
Module failure (converter)
Remedy
Check the following settings.
·The tools or the mass of the workpieces
Remove interference with the workpiece and peripheral device.
Correct the job whether load late does not exceed 100%.
(1)Check that 24V is generated to the brake bolt of the following terminals.
·Motor brake terminal
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, replace the following cables.
·The wire harness in the robot.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
Check the following settings.
·The tools or the mass of the workpieces
Remove interference with the workpiece and peripheral device.
Correct the job whether load late does not exceed 100%.
(1)Check that 24V is generated to the brake bolt of the following terminals.
·Motor brake terminal
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, replace the following cables.
·The wire harness in the robot.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
237 of 348