YASKAWA FS100 Maintenance Manual page 171

Hide thumbs Also See for FS100:
Table of Contents

Advertisement

Alarm
Alarm Name
Sub
Number
Code
4022
MEMORY ERROR
(PAINT SPECIAL FILE)
4023
MEMORY ERROR
(PAINT COND FILE)
4025
MEMORY ERROR
(INTERRUPT JOB FILE)
4028
MEMORY ERROR
(SENSOR MON COND
FILE)
4034
MEMORY ERROR
(ANTICIPATION OT FILE)
4035
MEMORY ERROR
(ANTICIPATION OG
FILE)
Meaning
Cause
Sub Code: Page number
Data error
Main CPU board failure
Sub Code: Page number
Data error
Main CPU board failure
Data error
Main CPU board failure
Data error
Main CPU board failure
Data error
Main CPU board failure
Data error
Remedy
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the paint special file in maintenance
mode, and then load the paint special file saved in the external memory device.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the paint condition file in maintenance
mode, and then load the paint condition file saved in the external memory
device.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the interrupt job file in maintenance mode,
and then load the interrupt job file saved in the external memory device.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the sensor monitoring condition file in
maintenance mode, and then load the sensor monitoring condition file saved in
the external memory device.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the anticipation output (OT) file in
maintenance mode, and then load the anticipation output (OT) file saved in the
external memory device.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the anticipation output (OG) file in
maintenance mode, and then load the anticipation output (OG) file saved in the
external memory device.
171 of 348