YASKAWA FS100 Maintenance Manual page 180

Hide thumbs Also See for FS100:
Table of Contents

Advertisement

Alarm
Alarm Name
Sub
Number
Code
10
11
12
48
4126
CANNOT EXECUTE
1
AUTO PMT
2
3
4
5
Meaning
Cause
Use memory is lacking and the
Software operation error
area could not be obtained.
occurred
The setting value of measurement
item (FT) is incorrect.
The data for the vision execution
Software operation error
command is incorrect.
occurred
The number of waiting commands
Software operation error
sent by Vision sensor exceeded
occurred
the limit.
System error
Software operation error
occurred
PBOX cannot be edited.
Setting error
The source job cannot be edited.
Setting error
The converted job cannot be
Setting error
edited.
The memory area for job area is
Software operation error
insufficient.
occurred
Remedy
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
Correct the setting value of a measurement item.
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)Check the command sent by Vision sensor
(3)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Check the following settings.
·I/O status of the edit prohibit signal
The edit prohibit signal cannot input.
(1)Check the following settings.
·The prohibit status of source job
If the source job is protected from editing, it cannot be edited.
(1)Check the following settings.
·The prohibit status of converted job
If the converted job is protected from editing, it cannot be edited.
(1)Reset the alarm.
(2)If the error occurs again, delete unused jobs.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job file.
In that case, delete the unused job.
(4)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
180 of 348

Advertisement

Table of Contents
loading

Table of Contents