YASKAWA FS100 Maintenance Manual page 151

Hide thumbs Also See for FS100:
Table of Contents

Advertisement

Alarm
Alarm Name
Sub
Number
Code
2
3
4
70
75
1221
ETHERNET INITIAL
1
PROCESS ERROR
2
3
Meaning
Cause
Incorrect setting of the subnet
Setting error
mask which is used in the
Ethernet function.
Incorrect setting of the default
Setting error
gateway which is used in the
Ethernet function.
Incorrect setting of the host
Setting error
address which is used in the
Ethernet function.
Incorrect setting of the host name
Setting error
which is used in the Ethernet
function.
Incorrect setting of the domain
Setting error
which is used in the Ethernet
function.
An error occurred in the device
Software operation error
initialization process of the
occurred
Ethernet function.
Main CPU board failure
An error occurred in the IP
Setting error
address setting process of the
Ethernet function.
Software operation error
occurred
Main CPU board failure
An error occurred in the subnet
Setting error
mask setting process of the
Ethernet function.
Software operation error
occurred
Remedy
(1)Check the following settings.
·Subnet mask of network in maintenance mode
(1)Check the following settings.
·Default gateway of network in maintenance mode
(1)Check the following settings.
·Server (host) of network in maintenance mode
(1)Check the following settings.
·Host name of network in maintenance mode
(1)Check the following settings.
·Domain name of network in maintenance mode
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller.
(1)Check the following settings.
·IP address setting of network in maintenance mode
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller.
(1)Check the following settings.
·Subnet mask of network in maintenance mode
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).