YASKAWA FS100 Maintenance Manual page 173

Hide thumbs Also See for FS100:
Table of Contents

Advertisement

Alarm
Alarm Name
Sub
Number
Code
4047
MEMORY ERROR
(MACRO DEFINITION
FILE)
4050
MEMORY ERROR
(AXIS I/O ALLOC FILE)
4051
MEMORY ERROR
(GUN COND. AUX. FILE)
4052
MEMORY ERROR
(TOOL INTERFERENCE)
4063
MEMORY ERROR
(CONVEYOR COND
SUPP.)
4065
MEMORY ERROR
(I/F PANEL FILE)
Meaning
Cause
Data error
Main CPU board failure
Data error
Main CPU board failure
Sub Code: File number
Data error
Main CPU board failure
Sub Code: File number
Data error
Main CPU board failure
Sub Code: File number
Data error
Main CPU board failure
Data error
Remedy
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the macro definition file in maintenance
mode, and then load the macro definition file saved in the external memory
device.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the axis motion I/O allocation file in
maintenance mode, and then load the axis motion I/O allocation file saved in
the external memory device.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the gun characteristics auxiliary file in
maintenance mode, and then load the gun characteristics auxiliary file saved in
the external memory device.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the tool interference file in maintenance
mode, and then load the tool interference file saved in the external memory
device.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the conveyor condition auxiliary file in
maintenance mode, and then load the conveyor condition auxiliary file saved in
the external memory device.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the I/F panel file in maintenance mode,
and then load the I/F panel file saved in the external memory device.