Alarm
Alarm Name
Sub
Number
Code
42
43
44
45
46
47
48
49
50
Meaning
Cause
Zero is set for the inertia of
Setting error
dynamics fixed model.
Designation error for dynamics-
Setting error
model calculation type
The optimized acceleration/
Setting error
deceleration control of speed limit
function is disabled.
The axis designation parameter
Setting error
for the speed limit function is not
set.
The setting in the mode
Setting error
designation parameter for the
speed limit function is incorrect.
Zero or negative value is set in
Setting error
the allowable braking torque
parameter for the speed limit
function.
Zero or a negative value is set in
Setting error
the speed adjustment ratio
parameter for the speed limit
function.
Zero or a negative value is set in
Setting error
the torque limit adjustment ratio
parameter for the acceleration/
deceleration tuning.
Zero or a negative value is set in
Setting error
the parameter that sets the
shortest acceleration/deceleration
time for when the excessive
torque is applied at the optimized
acceleration/deceleration.
Remedy
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
271 of 348