YASKAWA FS100 Maintenance Manual page 190

Hide thumbs Also See for FS100:
Table of Contents

Advertisement

Alarm
Alarm Name
Sub
Number
Code
-3
-4
-5
-6
-7
-8
-9
Meaning
Cause
The access to a job could not be
Software operation error
performed with the specified job
occurred
name.
Main CPU board failure
A job was newly created with the
Software operation error
same name of the job already
occurred
specified in the memory.
Main CPU board failure
A job was newly created with the
Software operation error
same name of the job already
occurred
specified in the memory.
Main CPU board failure
The allowable job registration
Setting error
area (memory) was exceeded.
A job that did not exist in the
Software operation error
memory was specified.
occurred
Main CPU board failure
An attempt was made to change
Setting error
the contents for the job prohibited
from being edited.
An error occurred during the
Software operation error
access to a job in handle value.
occurred
Remedy
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Check the following settings.
·Delete unused jobs.
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Check the following settings.
·Release the prohibition.
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
190 of 348