Alarm
Alarm Name
Sub
Number
Code
4344
LINEAR SERVOFLOAT
TRACKING ERROR
4345
LNK SERVOFLOAT
EXECUTE ERROR
4346
LNK SERVOFLOAT TRQ
LIMIT ERROR
4347
LNR SERVOFLOAT TRQ
LIMIT ERROR
4348
LNR SERVOFLOAT
COORD TYPE ERROR
4349
LNR SERVOFLOAT
TOOL POSE ERROR
4350
LNR SERVOFLOAT
EXECUTE ERROR
4351
DRIVE BELT SNAP
DETECT
4352
TWIN DRIVE OVER
DEVIATION
Meaning
Cause
Software operation error
occurred
Setting error
Setting error
Setting error
Setting error
Setting error
Setting error
Sub Code: Signifies the axis in
Connection failure
which the alarm occurred
Driving belt failure
Sub Code: Signifies the axis in
Connection failure
which the alarm occurred
Cable (failure)
(motor power cable)
Cable (failure)
(motor brake cable)
Servo control board failure
Module failure (amplifier)
Module failure
Remedy
Confirm the job settings so that excess load would not be applied to the axis in
the linear servo float.
Confirm the job settings so that excess load would not be applied to the axis in
the linear servo float.
Check the limit torque of the link servo float condition file.
Check the limit torque of the link servo float condition file.
Check the setting file of the job and the linear servo float.
Check the setting file of the job and the linear servo float.
Check the settings for jobs.
Check that the driving belt is not broken.
Check the driving belt.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Check U-, V- and W-phase of the motor power cable disconnection.
(2)If disconnection is found, replace the motor power cable.
(1) Check that the motor brake wire is not disconnected.
(2) If disconnected, replace the motor brake wire.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
(motor)
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
243 of 348