Alarm
Alarm Name
Sub
Number
Code
102
103
104
4132
TCP PROCESS ERROR
1
2
3
Meaning
Cause
The PCI write process was not
Software operation error
successfully completed in the
occurred
UDP process of the Ethernet
function.
Main CPU board failure
The transmission request of illegal
Software operation error
data length was received in the
occurred
UDP process of the Ethernet
function.
Main CPU board failure
The transmission request of illegal
Software operation error
data was received in the UDP
occurred
process of the Ethernet function.
Main CPU board failure
The socket table was not
Software operation error
successfully created in the TCP
occurred
process of the Ethernet function.
Main CPU board failure
An error occurred in the process
Software operation error
of the TCP server initialization of
occurred
the Ethernet function.
Main CPU board failure
An error occurred in connection
Software operation error
detecting process of TCP server
occurred
of the Ethernet function.
Main CPU board failure
Remedy
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller.