YASKAWA FS100 Maintenance Manual page 124

Hide thumbs Also See for FS100:
Table of Contents

Advertisement

Alarm
Alarm Name
Sub
Number
Code
1
320
VERIFY ERROR
1
(I/O MODULE)
2
Meaning
Cause
The CRC data in CMOS memory
Setting error
and the CRC data calculated by
the system software are
inconsistent.
Main CPU board failure
The I/O module connected to the
Setting error
serial bus #1 is different from the
function of the set I/O module.
Connection failure
Board failure (I/O module)
Main CPU board failure
The I/O module connected to the
Setting error
serial bus #2 is different from the
function of the set I/O module.
Connection failure
Board failure (I/O module)
Remedy
(1)Check the following settings.
·Set the security mode to MANAGEMENT MODE.
·Data rebuild in maintenance mode
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the controller. Save the CMOS.BIN before
replacement to be safe.
(1)Check the following settings.
·The rotary switch setting which specifies slot numbers of each I/O module
·I/O module settings in maintenance mode
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connecting or inserting state of the
following cables or connectors.
·IO module cable of the corresponding slot.
·Terminator
·24V power of the corresponding IO module.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the following board. Save the CMOS.BIN
before replace the board to be safe.
·Corresponding IO module
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the controller. Save the CMOS.BIN before
replacement to be safe.
(1)Check the following settings.
·The rotary switch setting which specifies slot numbers of each I/O module
·I/O module settings in maintenance mode
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connecting or inserting state of the
following cables or connectors.
·IO module cable of the corresponding slot.
·Terminator
·24V power of the corresponding IO module.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the following board. Save the CMOS.BIN
before replace the board to be safe.
·Corresponding IO module
124 of 348