Sub
05/08
Mode
Element
element
08
Setting
Process
Fuser
Temperature to start
mode
pre-running in ready
08
Setting
Process
Fuser
Contacting and
Mode
releasing setting of
pressure roller in
ready
08
Setting
Process
Fuser
Contacting and
Mode
releasing setting of
pressure roller in
ready
08
Setting
Process
Fuser
Temperature to switch
Mode
print speed
08
Setting
Process
Fuser
Temperature to switch
Mode
print speed
08
Setting
Process
Fuser
Switchover setting of
Mode
print speed
08
Setting
Process
Fuser
Switchover setting of
Mode
print speed
08
Setting
Process
Fuser
Fusing temperature
mode
during printing
Item
Subitem
Code
5239
5248
5248
Plain paper
5275
Plain paper
5275
Plain paper
5276
Plain paper
5276
Thick paper 4/Heat
5277
roller (Center)
Sub-
Default
Acceptable
Details
code
value
value
1
Low temperature
Refer to
0-20
contents
0
Normal temperature
1
0-2
1
Low temperature
1
0-2
0
Black/Heat roller
12
0-26
1
Color/Heat roller
12
0-26
0
Black/Heat roller
0
0-2
1
Color/Heat roller
0
0-2
0
Except for long-sized
13
0-16
paper
74
RAM
Contents
M
0: 70℃ 1: 75℃ 2: 80℃ 3: 85℃ 4: 90℃ 5: 95℃ 6:
100℃ 7: 105℃ 8: 110℃ 9: 115℃ 10: 120℃ 11:
125℃ 12: 130℃ 13: 135℃ 14: 140℃ 15: 145℃ 16:
150℃ 17: 155℃ 18: 160℃ 19: 165℃ 20: 170℃
<Default value>
25/30/35ppm: 12
45/50ppm: 15
M
0: Contacting 1: Released 2: Semi-contacting
M
0: Contacting 1: Released 2: Semi-contacting
M
0: 70℃ 1: 75℃ 2: 80℃ 3: 85℃ 4: 90℃ 5: 95℃ 6:
100℃ 7: 105℃ 8: 110℃ 9: 115℃ 10: 120℃ 11:
125℃ 12: 130℃ 13: 135℃ 14: 140℃ 15: 145℃ 16:
150℃ 17: 155℃ 18: 160℃ 19: 165℃ 20: 170℃ 21:
175℃ 22: 180℃ 23: 185℃ 24: 190℃ 25: 195℃ 26:
200℃
M
0: 70℃ 1: 75℃ 2: 80℃ 3: 85℃ 4: 90℃ 5: 95℃ 6:
100℃ 7: 105℃ 8: 110℃ 9: 115℃ 10: 120℃ 11:
125℃ 12: 130℃ 13: 135℃ 14: 140℃ 15: 145℃ 16:
150℃ 17: 155℃ 18: 160℃ 19: 165℃ 20: 170℃ 21:
175℃ 22: 180℃ 23: 185℃ 24: 190℃ 25: 195℃ 26:
200℃
M
0: Disabled
1: Enabled for 5 minutes after start-up
2: Enabled
M
0: Disabled
1: Enabled for 5 minutes after start-up
2: Enabled
M
0: 90℃ 1: 95℃ 2: 100℃ 3: 105℃ 4: 110℃ 5: 115℃
6: 120℃ 7: 125℃ 8: 130℃ 9: 135℃ 10: 140℃ 11:
145℃ 12: 150℃ 13: 155℃ 14: 160℃ 15: 165℃ 16:
170℃
Proce