Setup Table Files - Applied Biosystems 7900HT User Manual

Fast real-time pcr system and sds enterprise database
Hide thumbs Also See for 7900HT:
Table of Contents

Advertisement

Appendix A Software Reference

Setup Table Files

About the Setup
Table File Format
Format Overview
Conventions
A-4
Applied Biosystems 7900HT Fast Real-Time PCR System and SDS Enterprise Database User Guide
September 1, 2004 11:39 am, App_SWReference.fm
The SDS software features the ability to import setup table information into a plate
document from a tab-delimited text file. To guarantee a successful importation of
setup table data, the imported file must follow the setup table format outlined in this
section.
The information in the setup table file must be ordered according to the following
convention:
1. File Version (see page
Plate Characteristics
2. Plate Size (see page
3. Plate ID (see page
Detector Definitions
4. Number of Detectors (see page
5. Detectors List Header (see page
6. Detectors List (see page
Marker Definitions
7. Number of Markers (Allelic Discrimination Only) (see page
8. Markers List Header (Allelic Discrimination Only) (see page
9. Markers List (Allelic Discrimination Only) (see page
Well-Detector Information
10. Well-Detector List Header (see page
11. Well-Detector Definition List (see page
Well-Marker Information
12. Well-Marker List Header (Allelic Discrimination Only) (see page
13. Well-Marker Definition List (Allelic Discrimination Only) (see page
The following conventions are used in the rest of this section:
– Text appearing in bolded courier font must be applied to a setup
courier
table file exactly as appears in this document.
– Text appearing in italic courier font must be substituted with custom
italic
values when applied to a setup table file.
[ required text ]
information in setup table files. All information inside the brackets must be
present in the setup table file for the SDS software to import it.
{ optional text }
table files.
– The tab character (the equivalent of pressing the Tab key)
<tab>
– The carriage-return character (the equivalent of pressing the Enter key)
<cr>
To guarantee a successful importation of the setup table file into a
IMPORTANT!
plate document, the file must contain all the elements described in the following
section and in the order that they appear in this document.
DRAFT
A-5)
A-5)
A-5)
A-6)
A-6)
A-7)
A-10)
A-10)
– Text appearing between brackets is required
– Text appearing between braces is optional in setup
A-8)
A-8)
A-9)
A-12)