Honda 2005-2008 RX500 FA Service Manual page 424

Table of Contents

Advertisement

'61HN252' by American Honda Motor Co. - Page 424 of 540
[2005-2008] [TRX500 FA/FGA]
IGNITION SYSTEM
20-8
1 of 1
The ignition timing is correct if the "F" mark on the
flywheel aligns with the index mark on the rear
crankcase cover at idle.
Increase the engine speed and make sure the "F"
mark begins to move.
Coat a new O-ring with oil and install it onto the tim-
ing hole cap.
Install the timing hole cap and tighten it to the spec-
ified torque.
TORQUE: 10 N·m (1.0 kgf·m, 7 lbf·ft)
Install the recoil starter cover
(page 2-4).
http://services.honda.com/ServiceManual/SVC_MNL/61HN253/61HN2...
INDEX MARK
O-RING
TIMING HOLE CAP
"F" MARK
3/9/2008 11:21 PM