Honda 2005-2008 RX500 FA Service Manual page 412

Table of Contents

Advertisement

'61HN252' by American Honda Motor Co. - Page 412 of 540
[2005-2008] [TRX500 FA/FGA]
BATTERY/CHARGING SYSTEM
For the first check,
DO NOT charge the
battery before
testing; test it in an
"as is" condition.
19-6
1 of 1
Set the temperature switch to "HIGH" or "LOW"
depending on the ambient temperature.
Push in the appropriate test button for 3 seconds
and read the condition of the battery on the meter.
· To avoid damaging the tester, only test batteries
with an amperage rating of less than 30 Ah.
· Tester damage can result from overheating
when:
The test button is pushed in for more than 3
seconds.
The tester is used without being allowed to
cool for at least 1 minute when testing more
than one battery.
More than ten consecutive tests are performed
without allowing at least a 30-minute cool-
down period.
The result of a test on the meter scale is relative to
the amp. hour rating of the battery. Any battery
reading in the green zone is OK. Batteries should
only be charged if they register in the YELLOW or
RED zone.
http://services.honda.com/ServiceManual/SVC_MNL/61HN253/61HN2...
HIGH: 15°C (60°F) or higher
LOW: 15°C (60°F) or lower
TEST BUTTON
YELLOW (1)
RED (3, 2)
GREEN (+1, +2, +3)