BATTERY LINE
Measure the voltage between the Red wire terminal
of 3P (Black) connector and ground.
There should be battery voltage at all times.
GROUND LINE
Check the continuity between the Green wire termi-
nal of 3P (Black) connector and ground.
There should be continuity at all times.
CHARGING COIL LINE
Measure the resistance between the Yellow wire
terminals of 3P (GRAY) connector.
STANDARD: 0.1 1.0 Ω (at 20°C/68°F)
Check for continuity between each Yellow wire ter-
minal and ground.
There should be no continuity.
REMOVAL/INSTALLATION
Disconnect the regulator/rectifier 3P (Black) connec-
tor and 3P (Gray) connector.
Remove the regulator/rectifier mounting bolts.
http://services.honda.com/ServiceManual/SVC_MNL/61HN253/61HN2...
3P (GRAY) CONNECTOR
3P (BLACK)
CONNECTOR
3P (BLACK)
CONNECTOR
BOLTS
REGULATOR/RECTIFIER
3P (GRAY)
CONNECTOR