Smb Scan Dns Server Not Set; In Smb Scan, Server Connection Error; Problem With Storage Location Of Scanned Image In Smb Scan Server; Couldn't Get File/Folder Name Of Smb Scan Server - Fuji Xerox DocuCentre SC2020 Service Manual

Hide thumbs Also See for DocuCentre SC2020:
Table of Contents

Advertisement

DC SC2020
Version 1.1
2.3.5
Network-Related Details Check Flow
If the error persists after the action above is taken, ensure that the error replicates after the printer is pow-
ered off and then on, and then replace the ESS PWB.

031-527 SMB Scan DNS Server Not Set

BSD-ON:-
DNS server is not set.
Cause/Action
Recover after the [OK] or [Close] button is pressed or message is displayed for specified time. -Set DNS
address, or set forwarding destination server address as IP address. -Perform the following in sequence.
2.3 NET System Fault
Check2.3.5
Network-Related Details Check Flow
Take corrective actions at the host side.

031-528 In SMB scan, server connection error

BSD-ON:-
Cannot find SMB server.
Cause/Action
Recover after the [OK] or [Close] button is pressed or message is displayed for specified time.
1.Check if this device can communicate by network with the forwarding destination SMB server. For
example, check the following. -Check connection of network cable. -Check TCP/IP setting. -Check com-
munication with Port 137(UDP), 138(UDP), and 139(TCP).
2.For communication beyond the sub net, check setting of WINS server and if server name can be
resolved correctly.
3.Perform the following in sequence
2.3 NET System Fault Check
2.3.5
Network-Related Details Check Flow
If the error persists after the action above is taken, ensure that the error replicates after the printer is pow-
ered off and then on, and then replace the ESS PWB.
031-529 SMB Scan DNS Server Not Set
BSD-ON:-
Invalid password (Win9x).
Cause/Action
Recover after the [OK] or [Close] button is pressed or message is displayed for specified time. -Check if
password is correct. -Perform the following in sequence.
2.3 NET System Fault
Check2.3.5
Network-Related Details Check Flow
(PL
18.2)
(PL
18.2)
05/2014
2-42
If the error persists after the action above is taken, ensure that the error replicates after the printer is pow-
ered off and then on, and then replace the ESS PWB.
031-530 Problem with storage location of scanned image in SMB
scan server
BSD-ON:-
Problem with storage location.
Cause/Action
Recover after the [OK] or [Close] button is pressed or message is displayed for specified time. -Check if
storage location is correct. -Storage location you specified is DFS setting and check if it is linked to other
server. -Specify directly linked server, share name, and storage location. -Perform the following in
sequence.
2.3 NET System Fault Check
2.3.5
Network-Related Details Check Flow
If the error persists after the action above is taken, ensure that the error replicates after the printer is pow-
ered off and then on, and then replace the ESS PWB.

031-531 Couldn't get file/folder name of SMB scan server

BSD-ON:-
Couldn't get file/folder name of server.
Cause/Action
Recover after the [OK] or [Close] button is pressed or message is displayed for specified time. -Check
access right of the folder you specified. -Perform the following in sequence.
2.3 NET System Fault Check
2.3.5
Network-Related Details Check Flow
If the error persists after the action above is taken, ensure that the error replicates after the printer is pow-
ered off and then on, and then replace the ESS PWB.

031-532 Suffix of SMB scan file name/folder name is over limit

BSD-ON:-
Suffix of file name/folder name is over limit.
Cause/Action
Recover after the [OK] or [Close] button is pressed or message is displayed for specified time. -Change
file name/forwarding destination folder, or move or delete file in forwarding destination folder. -Perform
the following in sequence.
Troubleshooting
CHAIN 31
(PL
18.2)
(PL
18.2)
(PL
18.2)