2.2.3.3 +24VDC Power FIP

BSD-ON:CH1.2,CH1.1
Procedure
Turn ON the power. Is the voltage between LVPS J501-5(+) and GND(-), +24VDC?
Y
N
Is the voltage between LVPS J510-1 and J510-3, 220-240VAC?
Y
N
Proceed to
2.2.3.1
AC Power FIP.
Turn the Power OFF and remove LVPS J501. After 15 s or longer has passed, turn ON the
machine. Is the voltage between LVPS J501-5(+) and GND(-), +24VDC?
Y
N
Replace the LVPS.
(PL
18.3)
Check the +24VDC circuit for a short circuit in the frame by referring to Chapter 7 Wiring Data.
Check the circuit to the applicable component for an open circuit or poor contact by referring to Chapter 7
Wiring Data.