08H) Heat Roll Nc Sensor Differential Amp Fail; 09H) Fusing Unit Hot Not Ready Return Time Fail; 0Ah) Heat Roll Nc Sensor Broken Fail; 0Bh) Heat Roll Nc Sensor Broken Fail - Fuji Xerox DocuCentre SC2020 Service Manual

Hide thumbs Also See for DocuCentre SC2020:
Table of Contents

Advertisement

The Drawer Connector between the Fusing Unit and the Main Unit (DP/DJ600) for broken/bent
pins, foreign substances, burns, and etc.
Disconnection, shortage or contact failure of wire between Fusing Unit
Disconnection, shortage or contact failure of wire between Fusing Unit
PWB J414.
3.
If no problem is found, replace the following parts in sequence:
Fusing Unit
(PL
7.1)
LVPS
(PL
18.3)
DRIVE PWB
(PL
18.2)
ESS PWB
(PL
18.2)
4.
After replacing the Fusing Unit, enter CE Mode, go to Printer Diag > Parameter > Life > Fusing Unit
Print Count / Fusing Unit Time Count and initialize the Life Counters.

010-397 (08h) Heat Roll NC Sensor Differential Amp Fail

BSD-ON:CH10.3
Malfunction of temperature monitor AD value of Fusing Unit NC Sensor was detected for 10 consecutive
times.
NOTE: . To release this Fail, clear NVM[759-123] (Differential Amplifier Detection History) [0] after
removing the cause and turn the Power Off/On.
Cause/Action
1.
Clear the history at the NVM then turn the power OFF and ON.
2.
Turn OFF the power and check the following:
The Fusing Unit for improper installation
The Drawer Connector between the Fusing Unit and the Main Unit (DP/DJ600S) for broken/
bent pins, foreign substances, burns, and etc.
Disconnection, shortage or contact failure of wire between Fusing Unit
PWB P414.
3.
If no problem is found, replace the following parts in sequence:
Fusing Unit
(PL
7.1)
DRIVE PWB
(PL
18.2)
ESS PWB
(PL
18.2)
4.
After replacing the Fusing Unit, enter CE Mode, go to Printer Diag > Parameter > Life > Fusing Unit
Print Count / Fusing Unit Time Count and initialize the Life Counters.

010-397 (09h) Fusing Unit Hot Not Ready Return Time Fail

BSD-ON:CH10.3,CH10.2
The time taken to recover from High Temperature Not Ready state has exceeded the specified time.
Version 1.1
DC SC2020
Cause/Action
1.
Turn the power OFF and ON.
DJ600
and LVPS P2.
2.
Turn OFF the power and check the following:
DJ600S
and DRIVE
The Fusing Unit for improper installation
The Drawer Connector between the Fusing Unit and the Main Unit (DP/DJ600) for broken/bent
pins, foreign substances, burns, and etc.
Disconnection, shortage or contact failure of wire between Fusing Unit
Disconnection, shortage or contact failure of wire between Fusing Unit
PWB J414.
3.
If no problem is found, replace the following parts in sequence:
Fusing Unit
LVPS
DRIVE PWB
ESS PWB
4.
After replacing the Fusing Unit, enter CE Mode, go to Printer Diag > Parameter > Life > Fusing Unit
Print Count / Fusing Unit Time Count and initialize the Life Counters.

010-397 (0Ah) Heat Roll NC Sensor Broken Fail

BSD-ON:CH10.3
(Fusing Unit NC Sensor temperature- Fusing Unit Thermistor temperature) was 90 (NVM) degrees
or more for more than 10 consecutive times.
(Fusing Unit Thermistor temperature- Fusing Unit NC Sensor temperature) was 70 (NVM) degrees
or more for more than 10 consecutive times.
Cause/Action
1.
Turn the power OFF and ON.
DJ600S
and DRIVE
2.
Turn OFF the power and check the following:
The Fusing Unit for improper installation
The Drawer Connector between the Fusing Unit and the Main Unit (DP/DJ600) for broken/bent
pins, foreign substances, burns, and etc.
Disconnection, shortage or contact failure of wire between Fusing Unit
PWB P414.
3.
If no problem is found, replace the following parts in sequence:
Fusing Unit
DRIVE PWB
ESS PWB
4.
After replacing the Fusing Unit, enter CE Mode, go to Printer Diag > Parameter > Life > Fusing Unit
Print Count / Fusing Unit Time Count and initialize the Life Counters.

010-397 (0Bh) Heat Roll NC Sensor Broken Fail

05/2014
2-23
(PL
7.1)
(PL
18.3)
(PL
18.2)
(PL
18.2)
(PL
7.1)
(PL
18.2)
(PL
18.2)
DJ600
and LVPS P2.
DJ600S
and DRIVE
DJ600S
and DRIVE
CHAIN 10
Troubleshooting