Version 1.1
Figure 6 j0bs65017
Color Bar Screen
Figure 7 j0bs65018
Grayscale Screen
Figure 8 j0bs65019
6.5.11.3 Operating Explanation
Move to the next screen with the [Start] key. Go back to the previous screen with the [Stop] key.
(The display shall be all Red when entering from the Menu and the it shall return to the Panel Diag
Menu when the [Start] key is pressed at the Grayscale screen.)
Return to the Panel Diag Menu using the [Delete] key.
05/2014
6-276
6.5.12 Adjust Sense of Touch
6.5.12.1 Function Explanation
Acquire the PD4 (Y coordinate) voltage during the touch operation of the Panel and set the adjust-
ment value for determining whether the acquired value is standard value or above.
Maintain the adjusted value in NVM of the Touch Panel Device.
When touch operating the Panel, use the adjusted value that was set with this device and detect the
touch.
6.5.12.2 Screen Layout
NOTE: The default value is 2801.
6.5.12.3 Operating Explanation
Sensitivity adjustment value can be changed only with the numeric keypad.
The value range is from 0 (low) to 915 (high). If a number that exceeds the maximum value is
entered, the numeric keypad input will be invalid.
Set the value with the [OK] button/[Start] key and return to the Panel Diag Menu. The [x] button/
[Delete] key will not set the value and will return to the Panel Diag Menu.
Return the sensitivity to its default value by pressing the [All Clear] key.
6.5.12 Adjust Sense of Touch
Figure 1 j0bs65020