6.4.8.2 Digital Output
This function is used to check the operation of digital output (DO) component.The operation can be
enabled for every DO component, and whether or not the component is operating normally can be
judged by checking the operation from outside.
The Digital Output components can operate at the same time during the Digital Output test. When the
Interlock is opened during the Motor test, components stop their operations.
Table 1 Digital Output Parameter
Chain
Link
Parameter
042
001
Main Motor (126mm/s)
042
002
Main Motor (63mm/s)
042
003
Sub Motor (126mm/s)
042
004
Sub Motor (63mm/s)
042
005
Fusing Motor (126mm/s)
042
006
Fusing Motor (63mm/s)
042
007
YMC Link Solenoid
042
009
1st BTR Initialize
042
010
Fusing EXHAUST FAN
061
001
LPH forced lights (all-solid)
061
002
LPH forced lights (Cin50%)
061
003
LPH forced light (thyristor transfer)
071
001
#1 TRAY Feed Clutch
072
001
#2 Feed Motor 2-phase (CW 2) Feed Direction
072
002
#2 Feed Motor 2-phase (CCW 2) Lift Up Direction
072
003
#2 Feed Motor 1-2-phase (CW 1-2) Feed Direction
072
004
#2 Feed Motor 1-2-phase (CW 1-3) Lift Up direction
075
001
MSI Feed Clutch
077
002
Regi Clutch
077
003
Duplex Clutch
077
014
Invert Drive Motor (63-speed Fwd/max)
077
015
Invert Drive Motor (126-speed Fwd/max)
077
016
Invert Drive Motor (63-speed reverse/max )
077
017
Invert Drive Motor (126-speed reverse/max )
077
031
IOT Regi Stop Signal Output
077
033
TM T/A Motor Full Speed
077
034
TM T/A Motor Half Speed
091
001
BCR Y DC
091
002
BCR M DC
091
003
BCR C DC
091
004
BCR K DC
092
001
R_RAD_COM_DA (ADC/MOB Sensor LED)
Version 1.1
DC SC2020
Table 1 Digital Output Parameter
Chain
Link
Parameter
093
001
DISPENSE MOTOR-Y
093
002
DISPENSE MOTOR-M
093
003
DISPENSE MOTOR-C
093
004
DISPENSE MOTOR-K
093
005
DEVE BIAS-DC-YMC
093
006
DEVE BIAS-DC-K
093
007
DEVE BIAS-AC-YMC
093
008
DEVE BIAS-AC-K
094
001
2nd BTR (-)
094
002
2nd BTR (+)
094
003
1st BTR YMC Contact
094
004
1st BTR YMC Retract
094
005
1st BTR
Digital output test cases example
The following shows an example of running tests to verify the behavior Invert Drive Motor (63-speed Fwd/
MAX): tests to verify the operation of Sub Motor (126mm/s), 077-014 more here: 042-003.
1.
Enter the CE Mode. (Refer to
"6.4.2
2.
Make sure [Printer Diag] is selected, and then press [OK] button.
3.
[Down arrow] "IOT Diag" button to select, and then press [OK] button.
4.
[Down arrow] "Digital Output" button to select, and then press [OK] button.
05/2014
6-211
How to Enter the CE Mode")
Figure 1 j0bs64010
6.4.8.2 Digital Output