124-325 Billing Error
BSD-ON:CH3.4
Unable to auto restore the Billing Counter.
Cause/Action
1.
Turn the power OFF and ON.
2.
If the problem persists, replace the ESS PWB.
124-375 Product information error (Master)
BSD-ON:CH3.4
3-point check error of product unique information (Only Master is different).
Cause/Action
1.
Turn the power OFF and ON.
2.
6.4.10.2 Perform Copy Counter M to B/Copy Counter B to M.
3.
If the problem persists, replace the ESS PWB.
124-376 Product information error (Backup/IOT)
BSD-ON:CH3.4
3-point check error of product unique information (Either the Backup or IOT is different).
Cause/Action
1.
Turn the power OFF and ON.
2.
6.4.10.2 Perform Copy Counter M to B/Copy Counter B to M.
3.
If the problem persists, replace the ESS PWB.
124-377 Product information error (All)
BSD-ON:CH3.4
3-point check error of product unique information (All Master/Backup/IOT information is different).
Cause/Action
1.
Turn the power OFF and ON.
2.
6.4.10.2 Perform Copy Counter M to B/Copy Counter B to M.
3.
If the problem persists, replace the ESS PWB.
124-378 Billing meter type error (Different value)
Version 1.1
DC SC2020
(PL
18.2)
(PL
18.2)
(PL
18.2)
(PL
18.2)
BSD-ON:CH3.4
The Billing Meter Type information does not match in Master/Backup (Both format is correct).
Cause/Action
1.
Turn the power OFF and ON.
2.
If the problem persists, replace the ESS PWB.
124-379 Billing meter type error (Wrong format)
BSD-ON:CH3.4
The Billing Meter Type information does not match in Master/Backup (Both format is abnormal).
Cause/Action
1.
Turn the power OFF and ON.
2.
If the problem persists, replace the ESS PWB.
05/2014
2-113
(PL
18.2)
(PL
18.2)
CHAIN 124
Troubleshooting