Toner K Crum Not In Position; Toner Y Crum Data Broken; Toner M Crum Data Broken; Toner C Crum Data Broken - Fuji Xerox DocuCentre SC2020 Service Manual

Hide thumbs Also See for DocuCentre SC2020:
Table of Contents

Advertisement

DC SC2020
Version 1.1
2.Wipe the joining terminal between CRUM PWB of Toner Cartridge (C) and CRUM of Toner CRUM
Connector Assembly (C) with a dry cloth. (When cleaning, do not use Drum cleaner, etc.)
3.Check the following:
Disconnection, shortage or contact failure of wire between DRIVE PWB
CRUM Connector Assembly (C) J103.
Damage, contamination by foreign substances of the joining terminal between CRUM PWB of
Toner Cartridge (C) and CRUM of Toner CRUM Connector Assembly (C).
The Toner Cartridge (C) for improper installation
If no problem is found, replace the following parts in sequence:
Toner Cartridge (C)
(PL
5.1)
Toner CRUM Connector Assembly (C) (Dispenser Drive (CK))
DRIVE PWB
(PL
18.2)

093-973 Toner K CRUM Not In Position

BSD-ON:CH9.6
CRUM of Toner Cartridge (K) is not installed in the predetermined position (CRUM falling out).
Cause/Action
1.Remove and reinstall the Toner Cartridge (K).
2.Wipe the joining terminal between CRUM PWB of Toner Cartridge (K) and CRUM of Toner CRUM Con-
nector Assembly (K) with a dry cloth. (When cleaning, do not use Drum cleaner, etc.)
3.Check the following:
Disconnection, shortage or contact failure of wire between DRIVE PWB
CRUM Connector Assembly (K) J104.
Damage, contamination by foreign substances of the joining terminal between CRUM PWB of
Toner Cartridge (K) and CRUM of Toner CRUM Connector Assembly (K).
The Toner Cartridge (K) for improper installation
If no problem is found, replace the following parts in sequence:
Toner Cartridge (K)
(PL
5.1)
Toner CRUM Connector Assembly (K) (Dispenser Drive (CK))
DRIVE PWB
(PL
18.2)

093-980 Toner Y CRUM Data Broken

BSD-ON:CH9.5
Detected inequality in write data and read data of CRUM of Toner Cartridge (Y).
Cause/Action
Remove and reinstall the Toner Cartridge (Y) and check for improper installation.
05/2014
2-102
Replace Toner Cartridge (Y) if there is no problem after checking.
J406
and Toner

093-981 Toner M CRUM Data Broken

BSD-ON:CH9.5
Detected inequality in write data and read data of CRUM of Toner Cartridge (M).
Cause/Action
Remove and reinstall the Toner Cartridge (M) and check for improper installation.
(PL
5.3)
Replace Toner Cartridge (M) if there is no problem after checking.

093-982 Toner C CRUM Data Broken

BSD-ON:CH9.6
Detected inequality in write data and read data of CRUM of Toner Cartridge (C).
Cause/Action
Remove and reinstall the Toner Cartridge (C) and check for improper installation.
Replace Toner Cartridge (C) if there is no problem after checking.
J406
and Toner
(PL
5.3)
Troubleshooting

CHAIN 93

(PL
8.1)
(PL
8.1)
(PL
8.1)