REP 1.3.1 CIS Sensor Assembly

Parts List on
PL 1.3
Removal
WARNING
When turning OFF the power switch, check that the "Data"
lamp is OFF and that there is no Job in progress.
Turn OFF the Power Switch and make sure that the screen dis-
play or energy-saving LED is turned off.
Check that the power switch is OFF and unplug the power plug.
1.
Remove the Platen Cover or the DADF.
2.
Remove the IIT Top Cover.
(REP
1.2.1)
3.
Move the CIS Sensor Assembly to the center of IIT Base
Frame. (Figure 1)
Figure 1 j0bs40102
4.
Remove the CIS Sensor Assembly Belt from the CIS Sensor
Assembly. (Figure 2)
(1) Remove the CIS Sensor Assembly Belt in the direction of
the arrow.
(REP
56.1.1)
5.
Place the CIS Sensor Assembly turned over.
6.
Remove the Cable Guide. (Figure 3)
(1) Release the Hook (2) and remove the Cable Guide.
7.
Disconnect the CIS Sensor Assembly Connector and remove
the CIS Sensor Assembly. (Figure 4)
(1) Open the Connector Housing Block and disconnect the
Connector.
05/2014
4-6
Figure 2 j0bs40103
Figure 3 j0bs40104
Disassembly/Assembly and Adjustment
Figure 4 j0bs40105
Replacement
1.
To install, carry out the removal steps in reverse order.
2.
When connecting the CIS Sensor Assembly Connector, con-
nect the CIS Sensor Assembly Cable as shown in the figure.
(Figure 5)
Figure 5 0bs40106