(The first 2 digits "10" in "1000" are the upper digits, which indicates the LED Lamp Wire Har-
ness. The lower 2 digits "00" indicates that nothing is applicable (no failures).)
NOTE:
Perform IIT diagnostic and then call NVM [715-030] again (press the Change Settings button) to
check the value (diagnostic result).
Current value
Component Name
00
Not applicable (No errors)
01
Lamp (CIS Sensor Assy)
02
CIS Sensor Assy
03
Flexible Flat Cable (CIS Cable)
04
This value is not displayed
05
This value is not displayed
06
This value is not displayed
07
This value is not displayed
08
This value is not displayed
09
This value is not displayed
10
This value is not displayed
4.
After replacing the appropriate parts, again change the value for NVM [715-030] to '1' and then per-
form "NVM Write".
5.
Check that the current value column becomes '0'.
6.
If the problem persists after performing the above procedure, check the following:
Out of Lamp (CIS Sensor Assy) (IIT Output[062-002]).
Disconnection, shortage or contact failure of wire between CIS Sensor Assy
PWB
J15
(Especially check to see that the Flat Cable is not inserted in an angle).
7.
If no problem is found, replace the ESS PWB.
062-380 AGC Fail
BSD-ON:CH6.3
Insufficient lamp brightness was detected when performing AGC.
Initial Actions
Check whether there is something blocking the light and check the Lamp, Lens, Mirror, and White Color
Correction Plate for deterioration or contamination.
Procedure
1.
Turn the Power ON and enter CE Mode. Change the value for NVM [715-030] to '1' and then per-
form [NVM Write].
2.
A 3 or 4-digit number is displayed in the current value column.
Version 1.1
DC SC2020
Table 1
PL No.
-
PL 1.3
PL 1.3
PL 1.3
-
-
-
-
-
-
-
(PL
1.3)
J700
(PL
18.2)
3.
Check the upper 1 or 2 digits, or the lower 2 digits using the following table and replace the appro-
priate parts.
Sample Display
110 (3-digit display):
LED Lamp failure and LED Lamp Wire Harness is damaged or has poor contact.
(The first digit "1" in "110" is the upper digit, which indicates the LED Lamp ("0" in "01" is not
displayed). The lower 2 digits "10" indicates the LED Lamp Wire Harness.)
1000 (4-digit display):
The LED Lamp Wire Harness is damaged or has poor contact.
(The first 2 digits "10" in "1000" are the upper digits, which indicates the LED Lamp Wire Har-
ness. The lower 2 digits "00" indicates that nothing is applicable (no failures).)
NOTE:
Perform IIT diagnostic and then call NVM [715-030] again (press the Change Settings button) to
check the value (diagnostic result).
Current value
Component Name
00
Not applicable (No errors)
01
Lamp (CIS Sensor Assy)
02
CIS Sensor Assy
03
Flexible Flat Cable (CIS Cable)
04
This value is not displayed
05
This value is not displayed
06
This value is not displayed
07
This value is not displayed
08
This value is not displayed
and ESS
09
This value is not displayed
10
This value is not displayed
4.
After replacing the appropriate parts, again change the value for NVM [715-030] to '1' and then per-
form "NVM Write".
5.
Check that the current value column becomes '0'.
6.
If the problem persists after performing the above procedure, check the following:
Out of Lamp (CIS Sensor Assy) (IIT Output[062-002]).
Disconnection, shortage or contact failure of wire between CIS Sensor Assy
PWB
J15
(Especially check to see that the Flat Cable is not inserted in an angle).
7.
If no problem is found, replace the ESS PWB.
062-386 AOC Fail
BSD-ON:CH6.3
A CCD output error was detected when performing AOC.
05/2014
2-77
Table 1