Chain-Link
NVM Name
711-001
DADF Lead Reg. Adjustment (Side 1) (220.0 mm/s)
711-002
DADF Lead Reg. Adjustment (Side 1) (165.0 mm/s)
711-003
DADF Lead Reg. Adjustment (Side 1) (110.0 mm/s)
711-004
DADF Lead Reg. Adjustment (Side 1) (82.5 mm/s)
711-021
DADF Lead Reg. Adjustment (Side 2) (220.0 mm/s)
711-022
DADF Lead Reg. Adjustment (Side 2) (165.0 mm/s)
711-023
DADF Lead Reg. Adjustment (Side 2) (110.0 mm/s)
Version 1.1
DC SC2020
Table 1 NVM DADF
Setting
Default
Range
Value
step
105-135
120
0.1 mm
105-135
120
0.1 mm
105-135
120
0.1 mm
105-135
120
0.1 mm
105-135
120
0.1 mm
105-135
120
0.1 mm
105-135
120
0.1 mm
05/2014
6-31
Description
1) Default Value: 0 mm
(When 711-140 value is Default and 711-001 value is 120)
2) Adjustment Range (when 711-140 value is Default)
: +1.5 mm (105 pulse) / -1.5 mm (135 pulse)
3) Adjustment Range (when 711-140 value is 80 to 230)
: +5.5 mm (80 pulse) / -12.5 mm (230 pulse)
1) Default Value: 0 mm
(When 711-140 value is Default and 711-002 value is 120)
2) Adjustment Range (when 711-140 value is Default)
: +1.5 mm (105 pulse) / -1.5 mm (135 pulse)
3) Adjustment Range (when 711-140 value is 80 to 230)
: +5.5 mm (80 pulse) / -12.5 mm (230 pulse)
1) Default Value: 0 mm
(When 711-140 value is Default and 711-003 value is 120)
2) Adjustment Range (when 711-140 value is Default)
: +1.5 mm (105 pulse) / -1.5 mm (135 pulse)
3) Adjustment Range (when 711-140 value is 80 to 230)
: +5.5 mm (80 pulse) / -12.5 mm (230 pulse)
1) Default Value: 0 mm
(When 711-140 value is Default and 711-004 value is 120)
2) Adjustment Range (when 711-140 value is Default)
: +1.5 mm (105 pulse) / -1.5 mm (135 pulse)
3) Adjustment Range (when 711-140 value is 80 to 230)
: +5.5 mm (80 pulse) / -12.5 mm (230 pulse)
1) Default Value: 0 mm
(When 711-141 value is Default and 711-021 value is 120)
2) Adjustment Range (when 711-141 value is Default)
: +1.5 mm (105 pulse) / -1.5 mm (135 pulse)
3) Adjustment Range (when 711-141 value is 80 to 230)
: +5.5 mm (80 pulse) / -12.5 mm (230 pulse)
1) Default Value: 0 mm
(When 711-141 value is Default and 711-022 value is 120)
2) Adjustment Range (when 711-141 value is Default)
: +1.5 mm (105 pulse) / -1.5 mm (135 pulse)
3) Adjustment Range (when 711-141 value is 80 to 230)
: +5.5 mm (80 pulse) / -12.5 mm (230 pulse)
1) Default Value: 0 mm
(When 711-141 value is Default and 711-023 value is 120)
2) Adjustment Range (when 711-141 value is Default)
: +1.5 mm (105 pulse) / -1.5 mm (135 pulse)
3) Adjustment Range (when 711-141 value is 80 to 230)
: +5.5 mm (80 pulse) / -12.5 mm (230 pulse)