6.1.11 Warm Up Time
The time required before a print operation can be performed after the power is turned on is as follows.
Measurement
Rated at 20 degrees C/65% RH.
Conditions
Toner Recovery and Setup Cycle are not included.
Power ON after seasoning when the power has been OFF for 3 hours or longer.
Basic Configura-
Standard Main Unit
tion
Table 2
Configuration
Immediately after main power is turned ON*1
APO
39sec or less*1
*1: "Time from Power on to Standby on UI" or "Time from Power on to print out one sheet" - "Time from
Standby to print out one sheet"
Version 1.1
DC SC2020
Table 1
6.1.12 FCOT
<Definition>
The time that is required since the <Start> button is pressed until the trail edge of paper is output to the
defined output destination.
The measurement result is rounded to the first decimal place.
Prerequisite
Item
Contents
Document/Paper Size/Orienta-
A4 LEF Document, A4 LEF Paper
tion
Document size must be detected before the Start button is
pressed.
IIT/DADF Status
If the Platen is used, the document size is detected when the
Platen Cover is closed.
When using the DADF, the document must already be loaded.
Tray Used
Tray 1
Copy Side Settings
1->1 Sided Copy
Paper Quality Settings
Plain
Quantity Settings
1 set
Reduce / Enlarge
100% (excluding the case of 100% Fine Adjustment)
Output Color
Listed in Table 2
Output Tray
Output Tray
Output Orientation
Rear output (output orientation not specified)
State of Fusing Unit
The Fusing Unit must be in the Ready state
State of 1st BTR
1stBTR is Contact for Color priority, 1stBTR is Retract for
Black&White priority (Default)
State of the LPH
LPH must be in the Ready state
UI
4.3" WQVGA Color UI
Others
Other application functions or optional functions must not be set.
Background Suppression
OFF
ACC
OFF Auto Color Correction
20 ppm model FCOT
Document Set
No.
Platen/DADF
Output Tray
1
Platen
Output Tray
2
Output Tray
05/2014
6-13
Table 1
Table 2
Color Setting
BW
FC
Output Setting
(PS:126mm/s)
(PS:126mm/s)
Black (BW Mode) 8.6 sec or less
11.3 sec or less
Color
10.3 sec or less
10.8 sec or less