Chain-Link NVM Name
752-051
VH Upper Limit Value Calculation SW[C]
752-052
VH Upper Limit Value Calculation SW[K]
752-053
Ghost supported SW[YMC]
752-054
Ghost supported SW[K]
752-055
Barcode ModeSW
752-056
Custom Mode
752-057
Toner Recovery SW
752-058
Powe ON Determination for Recovery_SW
752-059
Installed Used CTRG supported SW
752-060
Remaining Amount Estimate Method SW
752-061
Remaining Notification SW
752-062
Filling Toner Amount supported SW
752-063
PreNear Correction during SW_EP Connection
752-064
Delta Humidity Selection SW_Setup Performing Require-
ment
752-065
Delta Humidity Selection SW_Target Value
752-066
Delta Humidity Selection SW_Disp
752-067
Delta Humidity Selection SW_Potential
752-068
Delta Humidity Selection SW_Device
752-069
Transfer VH Send Information SW
752-070
Transfer LUT_SW[Copy]
752-071
Transfer LUT_SW[Print]
752-072
ADC Sensor System Fail
752-073
ADC Sensor Fail Counter
752-074
ADC Potential Patch Fail Counter[Y]
752-075
ADC Potential Patch Fail Counter[M]
752-076
ADC Potential Patch Fail Counter[C]
Version 1.1
DC SC2020
Table 1 NVM 752_Process Control 1 List
Default
Minimum
Maximum
Value
value
value
Description
0
0
2
VH Upper Limit Calculate SW (0: VH Upper Limit Fixed Value, 1:
Variable Value with type/altitude correction, 2: Variable Value without
type/altitude correction)
0
0
2
VH Upper Limit Calculate SW (0: VH Upper Limit Fixed Value, 1:
Variable Value with type/altitude correction, 2: Variable Value without
type/altitude correction)
0
0
2
Ghost supported SW
0: OFF, 1: VH Lower Limit, 3: Fixed Delta V Offset
0
0
2
Ghost supported SW
0: OFF, 1: VH Lower Limit, 3: Fixed Delta V Offset
0
0
2
Barcode Mode Switch
Default Value 0: Follow the Mode, 1: Force ON, 2: Force OFF
1
0
1
0: Normal Mode, 1: Custom Mode
0
0
1
Normal Recovery·During Job Recovery Performing Switch (0: OFF,
1: ON)
0
0
1
Perform Determination SW for Power ON Determination (0: Not per-
formed, 1: Perform
0
0
1
Installed Toner Conveyance Path Filling Operation SW in used
CTRG
0
0
1
0: Disp Time Integrated Estimate, 1: ICDC Integrated Estimate
0
0
1
0: Normal, 1: Always PreNear
1
0
1
0: Filling Toner Amount supported Indication OFF, 1: Filling Toner
Amount supported Indication ON
0
0
1
SW to setup whether to conduct PreNear correction during EP Con-
nection
0: PreNear Correction OFF, 1: PreNear Correction ON
1
0
1
Delta Humidity Selection SW_Setup Performing Requirement
1
0
1
Delta Humidity Selection SW_Target Value
1
0
1
Delta Humidity Selection SW_Disp
1
0
1
Delta Humidity Selection SW_Potential
1
0
1
Delta Humidity Selection SW_Device
1
0
1
Transfer VH Send Information SW
1
0
1
Transfer LUT Selection SW
1
0
1
Transfer LUT Selection SW
0
0
65535
ADC Sensor System Fail
0
0
65535
ADC Sensor Fail Counter
0
0
65535
ADC Potential Patch Fail Counter
0
0
65535
ADC Potential Patch Fail Counter
0
0
65535
ADC Potential Patch Fail Counter
05/2014
6-99
Write
Allowed/
Can be
Unit
Protected
initialized
-
O
O
-
O
O
-
O
O
-
O
O
-
O
X
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
6.3.13 NVM 752_Process Control 1 List
General

Advertisement

Table of Contents
loading

Table of Contents