DC SC2020
Version 1.1
Chain-Link
NVM Name
711-215
DADF Stamp Position Adjustment Side 2 (T28)
711-220
Usage of DPM Control Parameter Instructed from the
Controller
711-221
DADF DPM Control Parameter
711-262
DOF Adjustment
711-272
Side 1 Side Regi Adjustment Value
(ADF-IIT Combine Adjustment Value Data 3)
711-274
Side 2 Side Regi Adjustment Value
(ADF-IIT Combine Adjustment Value Data 5)
711-276
ADF-IIT Combine Adjustment Value Data 7
711-277
ADF-IIT Combine Adjustment Value Data 8
711-278
ADF-IIT Combine Adjustment Value Data 9
711-279
ADF-IIT Combine Adjustment Value Data 10
711-280
ADF-IIT Combine Adjustment Value Data 11
711-281
ADF-IIT Combine Adjustment Value Data 12
711-282
ADF-IIT Combine Adjustment Value Data 13
711-283
ADF-IIT Combine Adjustment Value Data 14
711-284
ADF-IIT Combine Adjustment Value Data 15
711-297
Communication Fail Bypass
05/2014
6-34
Table 1 NVM DADF
Setting
Default
Range
Value
step
0-40
20
0.2 mm
0-1
1
-
0-255
101
-
0-10
5
-
0-240
120
-
0-240
120
-
0-255
0
-
0-255
0
-
0-255
0
-
0-255
0
-
0-255
0
-
0-255
0
-
0-255
0
-
0-255
0
-
0-255
0
-
0-1
0
-
Description
Sets the adjustment time so that the distance (step distance) is the same for every speed.
Adjustment Value (ms) = (NVM Input Value - NVM Default Value) / Transport Speed x 1000 x 0.2
(mm step).
0: Cont DPM Parameter Reject
1: Cont DPM Parameter Accept
100th Digit: Drive Type (0: High, 1: Middle, 2: Low)
10th Digit: Loop Control
1st Digit: Pre Regist Speed
Change the emphasis level of image processing.If 5 is considered as the mid level, as the number
becomes bigger (approaching 10), the emphasis level will become high. As the number becomes
smaller (approaching 0), the emphasis level will become low.
Side 1 Side Regi Adjustment Value
Side 2 Side Regi Adjustment Value
Adjustment Value Data 7 sent to IIT during ADF-IIT Combine
Adjustment Value Data 8 sent to IIT during ADF-IIT Combine
Adjustment Value Data 9 sent to IIT during ADF-IIT Combine
Adjustment Value Data 10 sent to IIT during ADF-IIT Combine
Adjustment Value Data 11 sent to IIT during ADF-IIT Combine
Adjustment Value Data 12 sent to IIT during ADF-IIT Combine
Adjustment Value Data 13 sent to IIT during ADF-IIT Combine
Adjustment Value Data 14 sent to IIT during ADF-IIT Combine
Adjustment Value Data 15 sent to IIT during ADF-IIT Combine
0: Communication Fail Bypass OFF
1: Communication Fail Bypass ON
General