Chain-Link NVM Name
752-971
MiniSetup Execution Requirement Stored Value [3][2]
752-972
MiniSetup Execution Requirement Stored Value [3][3]
752-973
MiniSetup Execution Requirement Stored Value [3][4]
752-974
Last Setup Speed Stored Value_Mid/End[YMC][0]
752-975
Last Setup Speed Stored Value_Mid/End[YMC][1]
752-976
Last Setup Speed Stored Value_Mid/End[YMC][2]
752-977
Last Setup Speed Stored Value_Mid/End[YMC][3]
752-978
Last Setup Speed Stored Value_Mid/End[YMC][4]
752-979
Last Setup Speed Stored Value_Mid/End[YMC][5]
752-980
Last Setup Speed Stored Value_Mid/End[YMC][6]
752-981
Last Setup Speed Stored Value_Mid/End[YMC][7]
752-982
Last Setup Speed Stored Value_Mid/End[YMC][8]
752-983
Last Setup Speed Stored Value_Mid/End[YMC][9]
752-984
Last Setup Speed Stored Value_Mid/End[K][0]
752-985
Last Setup Speed Stored Value_Mid/End[K][1]
752-986
Last Setup Speed Stored Value_Mid/End[K][2]
752-987
Last Setup Speed Stored Value_Mid/End[K][3]
752-988
Last Setup Speed Stored Value_Mid/End[K][4]
752-989
Last Setup Speed Stored Value_Mid/End[K][5]
752-990
Last Setup Speed Stored Value_Mid/End[K][6]
752-991
Last Setup Speed Stored Value_Mid/End[K][7]
752-992
Last Setup Speed Stored Value_Mid/End[K][8]
Version 1.1
DC SC2020
Table 1 NVM 752_Process Control 1 List
Default
Minimum
Maximum
Value
value
value
Description
0
0
255
Stored Value of MiniSetup Execution Requirement
0
0
255
Stored Value of MiniSetup Execution Requirement
0
0
255
Stored Value of MiniSetup Execution Requirement
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
0
0
1
Process Speed Stored Value after Mid/EndSetup is complete
0: 63mm/s, 1: 126mm/s
05/2014
6-127
Write
Allowed/
Can be
Unit
Protected
initialized
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
6.3.13 NVM 752_Process Control 1 List