DC SC2020
Version 1.1
Chain-Link NVM Name
742-191
Regi Assist Stop Timing Adjustment
(Tray1/MSI Common)
742-192
Regi Assist Stop Timing Adjustment
(MSI)
742-193
Regi Assist Stop Timing Adjustment
(1G)
742-194
Regi Assist Stop Timing Adjustment
(2G)
742-195
Regi Assist Stop Timing Adjustment
(3G)
742-196
Regi Assist Stop Timing Adjustment
(4G)
742-197
Regi Assist Stop Timing Adjustment
(Tray 1/126[mm/s]/Plain);
742-198
Regi Assist Stop Timing Adjustment
(MSI/126[mm/s]/Plain)
742-199
Regi Assist Stop Timing Adjustment
(MSI/63[mm/s]/Heavyweight)
742-200
Regi Assist Stop Timing Adjustment
(MSI/126[mm/s]/Heavyweight)
742-201
Regi Assist Stop Timing Adjustment
(MSI/63[mm/s]/Extra Heavyweight)
742-202
Regi Assist Stop Timing Adjustment
(MSI/63[mm/s]/Labels1)
742-203
Regi Assist Stop Timing Adjustment
(MSI/126[mm/s]/Labels1)
Table 1 NVM 742_Paper Handling List
Default
Minimum
Maximum
Value
value
value
Description
0
0
961
Adjusts the timing of Regi Feed start to stop (Tray1/Common MSI)_1[ms/step]
*Adjusting the value in the plus (+) direction delays the Stop timing.
0
0
961
Adjusts the timing of Regi Feed start to stop (MSI)_1[ms/step]
*Adjusting the value in the plus (+) direction delays the Stop timing.
0
0
961
Adjusts the timing of Regi Feed start to stop (1G)_1[ms/step]
*Adjusting the value in the plus (+) direction delays the Stop timing.
0
0
961
Adjusts the timing of Regi Feed start to stop (2G)_1[ms/step]
*Adjusting the value in the plus (+) direction delays the Stop timing.
0
0
961
Adjusts the timing of Regi Feed start to stop (3G)_1[ms/step]
*Adjusting the value in the plus (+) direction delays the Stop timing.
0
0
961
Adjusts the timing of Regi Feed start to stop (4G)_1[ms/step]
*Adjusting the value in the plus (+) direction delays the Stop timing.
0
0
395
Adjusts the timing of when the Tray1 Feed CL should stop after the Regi Feed starts (Tray1/126[mm/s]/
Plain)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the Tray1 Feed CLL OFF timing.
0
0
526
Adjusts the timing of when the MSI Feed CL should stop after the Regi Feed starts (MSI/126[mm/s]/
Plain)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
0
0
961
Adjusts the timing of when the MSI Feed CL should stop after the Regi Feed starts (MSI/126[mm/s]/
Heavyweight1)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
0
0
526
Adjusts the timing of when the MSI Feed CL should stop after the Regi Feed starts (MSI/126[mm/s]/
Heavyweight1)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
0
0
961
Adjusts the timing of when the MSI Feed CL should stop after the Regi Feed starts (MSI/63[mm/s]/
Extra Heavyweight)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
0
0
961
Adjusts the timing of when the MSI Feed CL should stop after the Regi Feed starts (MSI/126[mm/s]/
Labels1)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
0
0
526
Adjusts the timing of when the MSI Feed CL should stop after the Regi Feed starts (MSI/126[mm/s]/
Labels1)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
05/2014
6-50
General
6.3.6 NVM 742_Paper Handling List
Write
Allowed/
Can be
Protected
initialized
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O