DC SC2020
Version 1.1
6.5.9 Buzzer Test
6.5.9.1 Function Explanation
Perform buzzer sounding and buzzer stop test.
The buzzer volume can be switched between 3 volumes: Low, Mid, High
The buzzer will sound by sounding instructions and will stop sounding by stopping the buzzer. Do
not stop the buzzer sound automatically.
Enable the buzzer volume to be specified and buzzer to be turned on/off using the Hardware Key.
6.5.9.2 Screen Layout
NOTE: The default value is 1.
Figure 1 j0bs65010
6.5.9.3 Operating Explanation
Adjust the volume with Spinbox.1: Volume Low, 2: Volume Mid, 3:Volume High
Volume adjustment can be done using the numeric keypad as well. If a number that exceeds the
maximum value is entered, the numeric keypad input will be invalid. Numeric keypad [0] is invalid as
well.
Sound the buzzer by pressing the [Start] button.
The buzzer will stop by pressing the [Stop] button.
The [Stop] button should always be enabled. In other words, buzzer stop instructions should always
be enabled even if the buzzer is not sounding.
The [Start] key/[Stop] key of the Hardware Key shall also be able to control buzzer sounding instead
of the [Start]button/[Stop]button.
Return to the Panel Diag Menu using the [<-] button.
By pressing the [Delete] key, the volume will return to default.
Disable the "+"/"-" button display when the counter value reaches its Max/Min.
05/2014
6-274
6.5.10 Brightness Test
6.5.10.1 Function Explanation
Perform Panel Device brightness test.
The value changed with the Panel diagnosis function will not be reflected on the system data since
the purpose is to diagnose. The Panel brightness adjustment is open to KO and it can be set from
the corresponding screen.
6.5.10.2 Screen Layout
NOTE: The default value is 1.
6.5.10.3 Operating Explanation
Adjust the brightness with Spinbox. The value range is from 1 (dark) to 10 (bright).
The brightness can be changed with the numeric keypad as well. If a number that exceeds the max-
imum value is entered, the numeric keypad input will be invalid. The numeric keypad [0] of first row
is invalid as well.
Return to the Panel Diag Menu using the [<-] button.
By pressing the [Delete] key, the brightness will return to default.
Disable the "+"/"-" button display when the counter value reaches its Max/Min.
6.5.9 Buzzer Test
Figure 1 j0bs65011
General