6.5.7 Touch Screen Test
6.5.7.1 Function Explanation
Display the Touch mark on the LCD and compare to see if the place matches with the place the user
has touched. If it matches after comparing, change the Touch mark color to indicate that it has been
touched correctly. Do not change the color of the Touch mark if it does not match.
6.5.7.2 Screen Layout
1.
Switch to the touch test screen when the Menu is selected. (It will automatically switch to this screen
once the touch correction is completed)
Figure 1 j0bs65007
2.
The color can be changed by touching.
Figure 2 j0bs65008
6.5.7.3 Operating Explanation
Refer to Operation Flow of the Screen Layout for basic operation specifications.
Guide the Touch in a Z shape (Parallel from the left (upper left) to right (lower right).
This test should be able to be terminated if any abnormality is detected on the Touch. The method
of termination shall be the "Delete" key of the Hardware Key and not the Touch Panel.
Return to the Panel Diag Menu after the lower right mark is touched (Return to the Menu when the
lower right mark is touched even if everything not been touched).
Display the corrected coordination with a blue "+" mark.
(In most cases, do not display if it was started up from the Maintenance Menu.)
Version 1.1
DC SC2020
6.5.8 LED Test
6.5.8.1 Function Explanation
Perform light test for the LED installed in the Panel Device to see if it turns ON/OFF.
Energy saving LED is connected to the port in the ESS board. Due to this, the LED light control uses
USB I/F and the Panel Device instructs the energy saving LED control to the ESS.
6.5.8.2 Screen Layout
6.5.8.3 Operating Explanation
Each button forms 1 group button (referred to as LED button group hereinafter) and operates alter-
natively. The default display is All Off.
If there is anything selected from the LED button group, turn ON the corresponding LED. If it is not
selected, turn OFF the corresponding LED.
If the [ALL LED] button is selected, select the LED button group and turn all LEDs ON. If there is a
LED button that is not selected, turn OFF the [ALL LED] button.
Return to the Panel Diag Menu using the [<-]button/[Delete]key.
Disable the display of the Energy Saving Button.
05/2014
6-273
Figure 1 j0bs65009
6.5.7 Touch Screen Test