6.3.13 NVM 752_Process Control 1 List
Chain-Link NVM Name
752-001
Disp Control SW [YMC]
752-002
Disp Control SW [K]
752-003
Potential Control SW
752-004
ADC Tone Control SW
752-005
TRC Manual Adjustment SW
752-006
Calibration SW
752-007
Empty Detection SW
752-008
ProConSetup_SW
752-009
MiniSetup_SW
752-010
MidSetup_SW
752-011
EndSetup_SW
752-012
TCSetup_SW
752-013
MiniSetup Forced Execution Flag
752-014
Front_Interlock_Open_MiniSetup_SW
752-015
BW_MiniSetup Priority SW
752-016
Setup Continuous Execution after Mini SW
752-017
CycleDown_SW after MiniSetup
752-018
MidSetup_Vcln Create SW
752-019
EndSetup_Vcln Create SW
752-020
TCSetup_Vcln Create Switch
752-021
Vcln Sync Calculation Switch
752-022
High Image Density Mix Switch
752-023
Vdeve Limit Band Switch
752-024
Deve_Bias_AC_SW
752-025
ADCLED_SW
752-026
Delta RADC_Potential_Target All Correcting SW
752-027
Delta RADC_Tone_Target All Correcting SW[Patch1]
752-028
Delta RADC_Tone_Target All Correcting SW[Patch2]
752-029
Delta RADC_Tone_Target All Correcting SW[Patch3]
Version 1.1
DC SC2020
Table 1 NVM 752_Process Control 1 List
Default
Minimum
Maximum
Value
value
value
Description
2
0
2
Toner Refill Control Mode Switch
2
0
2
Toner Refill Control Mode Switch
0
0
2
Potential Control Mode Switch
0
0
1
ADC Tone Control Mode Switch
0
0
1
The TRC manual adjustment mode switch.
0
0
3
Auto Gradation Adjustment Application Switch
0
0
2
Empty Detection Switch (0: OFF 1: ON 2: Detection OFF)
1
0
1
Switch for all Procon Setup (0: OFF, 1: ON)
1
0
1
MiniSetup Switch (0: OFF, 1: ON)
1
0
1
MidSetup Switch (0: OFF, 1: ON)
1
0
1
EndSetup Switch (0: OFF, 1: ON)
0
0
1
TCSetup Switch (0: OFF, 1: ON)
1
0
2
MiniSetup Force Execution Flag (0: Force Execute, 1: Enter
FC_MiniSetup, 2: Enter BW_MiniSetup)
0
0
1
Switch to Allow/Forbid MiniSetup Execution when Power ON/Sleep
Recovery in Front Interlock Open Status (0: Allow: 1 Disable)
1
0
1
BW_MiniSetup Priority Switch (0: OFF, 1: ON)
0
0
1
Setup Continuous Execution SW after Mini (0: [Prohibit, 1: Allow)
0
0
1
CycleDown_SW after MiniSetup (0: Normal Operation, 1: Always
CycleDown)
0
0
2
MidSetup Vcln Create Switch (0: Do not always create Vcln, 1:
Always create Vcln, 2: Create Vcin according to Flag)
2
0
2
EndSetup Vcln Create Switch (0: Do not always create Vcln, 1:
Always create Vcln, 2: Create Vcin according to Flag)
0
0
2
TCSetup Vcln Create Switch (0: Do not always create Vcln, 1:
Always create Vcln, 2: Create Vcin according to Flag)
0
0
1
Vcln Sync Calculation Switch (0: Use All Vcln Mean, 1: Use Vcln
Sync)
1
0
2
Switch to determine the Mixing Execution during High Image Density
Output (0: No Mixing, 1 With Mixing, 2: With Mixing & Toner Band)
0
0
1
Vdeve Limit Band Switch (0: OFF, 1: ON)
1
0
1
Developing Bias AC Mode Switch (0: OFF, 1: ON)
0
0
2
ADCLED ON/OFF Switch
0
0
1
Delta RADC_Potential_Target All Correcting Switch
1
0
1
Delta RADC_Tone_Target All Correcting Switch
1
0
1
Delta RADC_Tone_Target All Correcting Switch
1
0
1
Delta RADC_Tone_Target All Correcting Switch
05/2014
6-97
Write
Allowed/
Can be
Unit
Protected
initialized
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O