Fuji Xerox DocuCentre SC2020 Service Manual page 498

Hide thumbs Also See for DocuCentre SC2020:
Table of Contents

Advertisement

DC SC2020
Version 1.1
Chain-Link NVM Name
752-077
ADC Potential Patch Fail Counter[K]
752-078
ADC Tone Patch Fail_All Tone[Y]
752-079
ADC Tone Patch Fail_All Tone[M]
752-080
ADC Tone Patch Fail_All Tone[C]
752-081
ADC Tone Patch Fail_All Tone[K]
752-082
ADC Tone Patch Fail Counter [Y][Patch1]
752-083
ADC Tone Patch Fail Counter [Y][Patch2]
752-084
ADC Tone Patch Fail Counter [Y][Patch3]
752-085
ADC Tone Patch Fail Counter [Y][Patch4]
752-086
ADC Tone Patch Fail Counter [M][Patch1]
752-087
ADC Tone Patch Fail Counter [M][Patch2]
752-088
ADC Tone Patch Fail Counter [M][Patch3]
752-089
ADC Tone Patch Fail Counter [M][Patch4]
752-090
ADC Tone Patch Fail Counter [C][Patch1]
752-091
ADC Tone Patch Fail Counter [C][Patch2]
752-092
ADC Tone Patch Fail Counter [C][Patch3]
752-093
ADC Tone Patch Fail Counter [C][Patch4]
752-094
ADC Tone Patch Fail Counter[K][Patch1]
752-095
ADC Tone Patch Fail Counter[K][Patch2]
752-096
ADC Tone Patch Fail Counter[K][Patch3]
752-097
ADC Tone Patch Fail Counter[K][Patch4]
752-098
ADC_TC Patch Fail Counter[Y]
752-099
ADC_TC Patch Fail Counter[M]
752-100
ADC_TC Patch Fail Counter[C]
752-101
ADC_TC Patch Fail Counter[K]
752-102
ADC_Vpatch Storing Address
752-103
Creating Flag Toner Band[Y]
752-104
Creating Flag Toner Band[M]
752-105
Creating Flag Toner Band[C]
752-106
Creating Flag Toner Band[K]
752-107
No. of MiniSetup Execution_Total[BW]
752-108
No. of MiniSetup Execution_Total[FC]
752-109
No. of MidSetup Execution_Total[BW]
752-110
No. of MidSetup Execution_Total[FC]
752-111
No. of EndSetup Execution_Total[BW]
752-112
No. of EndSetup Execution_Total[FC]
752-113
No. of TCSetup Execution_Total[BW]
05/2014
6-100
Table 1 NVM 752_Process Control 1 List
Default
Minimum
Maximum
Value
value
value
Description
0
0
65535
ADC Potential Patch Fail Counter
0
0
1
ADC Tone Patch Fail_All Tone (either one occur)
0
0
1
ADC Tone Patch Fail_All Tone (either one occur)
0
0
1
ADC Tone Patch Fail_All Tone (either one occur)
0
0
1
ADC Tone Patch Fail_All Tone (either one occur)
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC Tone Patch Fail Counter
0
0
65535
ADC_TC Patch Fail Counter
0
0
65535
ADC_TC Patch Fail Counter
0
0
65535
ADC_TC Patch Fail Counter
0
0
65535
ADC_TC Patch Fail Counter
0
0
4294967295 ADC Patch Output Measurement Value Storing Address on RAM
(For Soft Debug)
0
0
1
Flag for Toner Band Create Determination
0
0
1
Flag for Toner Band Create Determination
0
0
1
Flag for Toner Band Create Determination
0
0
1
Flag for Toner Band Create Determination
0
0
65535
Total No. of Execution of MidSetup
0
0
65535
Total No. of Execution of MidSetup
0
0
65535
Total No. of Execution of MidSetup
0
0
65535
Total No. of Execution of MidSetup
0
0
65535
Total No. of Execution of EndSetup
0
0
65535
Total No. of Execution of EndSetup
0
0
65535
Total No. of Execution of TCSetup
General
6.3.13 NVM 752_Process Control 1 List
Write
Allowed/
Can be
Unit
Protected
initialized
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O

Advertisement

Table of Contents
loading

Table of Contents