Deve Hsg C Life End; Deve Hsg K Life End; Toner Y Crum Communication Fail; Version 1.1 - Fuji Xerox DocuCentre SC2020 Service Manual

Hide thumbs Also See for DocuCentre SC2020:
Table of Contents

Advertisement

DC SC2020

Version 1.1

Cause/Action
Replace the Deve Unit (M).
(PL
5.1)
After replacing, enter CE Mode, go to Printer Diag > Parameter > Life > Deve HSG PV M and initialize the
Life Counter.

093-946 Deve HSG C Life End

BSD-ON:-
Indicates Deve HSG C reached its usage limit. (Restrict Print operation)
Cause/Action
Replace the Deve Unit (C).
(PL
5.1)
After replacing, enter CE Mode, go to Printer Diag > Parameter > Life > Deve HSG PV C and initialize the
Life Counter.

093-947 Deve HSG K Life End

BSD-ON:-
Indicates Deve HSG K reached its usage limit. (Restrict Print operation)
Cause/Action
Replace the Deve Unit (K).
(PL
5.1)
After replacing, enter CE Mode, go to Printer Diag > Parameter > Life > Deve HSG PV K and initialize the
Life Counter.

093-950 Toner Y CRUM Communication Fail

BSD-ON:CH9.5
Detected communication abnormality with CRUM of Toner Cartridge (Y).
Cause/Action
1.Turn the power OFF and ON.
2.Turn OFF the power and check the following:
Disconnection, shortage or contact failure of wire between DRIVE PWB
CRUM Connector Assembly (Y) J101.
Damage, contamination by foreign substances of the joining terminal between CRUM PWB of
Toner Cartridge (Y) and CRUM of Toner CRUM Connector Assembly (Y).
Uncleanness, dislocation of CRUM PWB of Toner Cartridge (Y).
The Toner Cartridge (Y) for improper installation
If no problem is found, replace the following parts in sequence:
Toner Cartridge (Y)
(PL
5.1)
05/2014
2-100
Toner CRUM Connector Assembly (Y) (Dispenser Drive (YM))
DRIVE PWB

093-951 Toner M CRUM Communication Fail

BSD-ON:CH9.5
Detected communication abnormality with CRUM of Toner Cartridge (M).
Cause/Action
1.Turn the power OFF and ON.
2.Turn OFF the power and check the following:
Disconnection, shortage or contact failure of wire between DRIVE PWB
CRUM Connector Assembly (M) J102.
Damage, contamination by foreign substances of the joining terminal between CRUM PWB of
Toner Cartridge (M) and CRUM of Toner CRUM Connector Assembly (M).
Uncleanness, dislocation of CRUM PWB of Toner Cartridge (M).
The Toner Cartridge (M) for improper installation
If no problem is found, replace the following parts in sequence:
Toner Cartridge (M)
Toner CRUM Connector Assembly (M) (Dispenser Drive (YM))
DRIVE PWB

093-952 Toner C CRUM Communication Fail

BSD-ON:CH9.6
Detected communication abnormality with CRUM of Toner Cartridge (C).
Cause/Action
1.Turn the power OFF and ON.
2.Turn OFF the power and check the following:
Disconnection, shortage or contact failure of wire between DRIVE PWB
CRUM Connector Assembly (C) J103.
J405
and Toner
Damage, contamination by foreign substances of the joining terminal between CRUM PWB of
Toner Cartridge (C) and CRUM of Toner CRUM Connector Assembly (C).
Uncleanness, dislocation of CRUM PWB of Toner Cartridge (C).
The Toner Cartridge (C) for improper installation
If no problem is found, replace the following parts in sequence:
Toner Cartridge (C)
Toner CRUM Connector Assembly (C) (Dispenser Drive (CK))
DRIVE PWB
(PL
18.2)
(PL
5.1)
(PL
18.2)
(PL
5.1)
(PL
18.2)
Troubleshooting
CHAIN 93
(PL
5.3)
J405
and Toner
(PL
5.3)
J406
and Toner
(PL
5.3)